Table 1. Powertrain Troubleshooting Procedures - Continued.
Figure 46. Guard and Retaining Hardware.

Field Maintenance Manual 1 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  596    597    598    599    600  601  602    603    604    605    606  
img
. . . . . . .
TM 5-2410-241-23-1
0020
Table 1. Powertrain Troubleshooting Procedures - Continued.
0020
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1402-3 Transmission Sole-
10. Remove rear floor plate (WP
noid Valve #2 Voltage
0231).
Above Normal - Contin-
ued
11. Disconnect platform harness con-
nector MA-C7 (WP 0018, Figure
53) from transmission jumper har-
ness connector MP-C2 (WP 0018,
Figure 54).
12. Using a digital multimeter (WP
1. If continuity is found, proceed to
0296), test for continuity between
step 13.
pin 2 on platform harness connec-
2. If continuity is NOT found, replace
tor to transmission jumper harness
platform harness (WP 0209).
MA-C7 (WP 0018, Figure 53) and
Ensure all harness connectors are
pin 29 on platform harness con-
reconnected. Verify correct opera-
nector MA-C14 (WP 0018,
tion of machine (TM 5-2410-241-
Figure 33).
10).
13. Using a digital multimeter (WP
1. If continuity is NOT found, proceed
0296), test for continuity between
to step 14.
pin 29 on platform harness con-
2. If continuity is found, replace plat-
nector MA-C14 (WP 0018, Figure
form harness (WP 0209). Ensure
33) and all other pins in platform
all harness connectors are recon-
harness connector MA-C14 (WP
nected. Verify correct operation of
0018, Figure 33).
machine (TM 5-2410-241-10).