Table 1. Powertrain Troubleshooting Procedures - Continued.
0020
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1402-5 Transmission Sole-
1. Connect MSD (WP 0016), select
1. If active 1402-5 code is present,
noid Valve #2 Current
Powertrain D7 ECM, and check for
proceed to step 2.
Below Normal
Diagnostic Codes (WP 0013).
2. If no active codes are present, the
problem does NOT exist at this
time. Resume normal operation.
2. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-241-10).
3. Remove four bolts (Figure 48,
Item 2), washers (Figure 48,
Item 3), and guard (Figure 48,
Item 1) from machine.
Figure 48. Guard and Retaining Hardware.
0020
0020-173