• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 65. Guard, Plate, and Retaining Hardware
Figure 67. Guard, Plate, and Retaining Hardware.

Field Maintenance Manual 1 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  630    631    632    633    634  635  636    637    638    639    640  
img
. . .
TM 5-2410-241-23-1
0020
Table 1. Powertrain Troubleshooting Procedures - Continued.
0020
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1404-5 Transmission Sole-
1. Connect MSD (WP 0016), select
1. If active 1404-5 code is present,
noid Valve #4 Current
Powertrain D7 ECM, and check for
proceed to step 2.
Below Normal
Diagnostic Codes (WP 0013).
2. If no active codes are present, the
problem does NOT exist at this
time. Resume normal operation.
2. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-241-10).
3. Remove four bolts (Figure 66,
Item 2), washers (Figure 66,
Item 3), and guard (Figure 66,
Item 1) from machine.
Figure 66. Guard and Retaining Hardware.
0020
0020-204


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.