Table 2. Chassis Troubleshooting Procedures - Continued.
Figure 1. Hydraulic Lockout Switch.

Field Maintenance Manual 1 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  675    676    677    678    679  680  681    682    683    684    685  
img
. . . . . . . . . . .
TM 5-2410-241-23-1
0021
Table 2. Chassis Troubleshooting Procedures - Continued.
0021
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
324-3 Action Lamp Voltage
4. Disconnect instrument panel har-
Above Normal - Contin-
ness action lamp connector E-
ued
C25 (WP 0018, Figure 82) from
action lamp (WP 0262).
5. Using digital multimeter (WP
1.
If continuity is NOT found, replace
0296), test for continuity between
instrument panel harness
PINK WIRE on instrument panel
(WP 0260). Ensure all harness
harness action lamp connector E-
connectors are reconnected. Ver-
C25 (WP 0018, Figure 82) and
ify correct operation of machine
pin 13 on dash monitor connector
(TM 5-2410-241-10).
E-C7 (WP 0018, Figure 5).
2.
If continuity is found, proceed to
step 6.
6. Using digital multimeter (WP
1.
If continuity is found, replace
0296), test for continuity between
instrument panel harness
pin 13 on dash monitor connector
(WP 0260). Ensure all harness
E-C7 (WP 0018, Figure 5) and all
connectors are reconnected. Ver-
other pins in dash monitor con-
ify correct operation of machine
nector E-C7 (WP 0018, Figure 5).
(TM 5-2410-241-10).
2.
If continuity is NOT found, replace
dash monitor ECM (WP 0262).
Ensure all harness connectors
are reconnected. Verify correct
operation of machine (TM 5-2410-
241-10).
490-3 Hydraulic Lockout
1. Connect MSD (WP 0016). Select
1. If active 490-3 code is present,
Solenoid Voltage Above
CAT Monitoring System D7R
proceed to step 2.
Normal
ECM and check for Diagnostic
2. If no active codes are present,
Codes or Event Codes (WP
problem does NOT exist at this
0013).
time. Resume normal operation.
2. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-241-10).
3. Remove right platform access
panel (WP 0213).
4. Disconnect RH console harness
hydraulic lockout switch connec-
tor RW-C7 (WP 0018, Figure 89)
from hydraulic lockout switch
(WP 0018, Figure 91).
5. Ensure hydraulic lockout switch is
in LOCKED (Figure 1, Item 2)
position.