TM 5-2410-241-23-1
0039
Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued.
LOCATION
ITEM TO
ITEM
NOT FULLY MISSION
CHECK/
SERVICE
NO.
INTERVAL
PROCEDURE
CAPABLE IF:
N OT E
15
Every 1,000
Torque
(Cont) Service
Converter
Scavenge screen may fall out of hose when removed from torque
Hours or six
Scavenge
converter housing.
months
Screen - Clean
c. Remove four bolts (Figure 7,
Item 3), washers (Figure 7, Item 2),
two split clamps and hose (Figure 7,
Item 1) from torque converter housing
(Figure 7, Item 4).
d. Remove torque converter washer
and scavenge screen (Figure 7,
Item 5) from hose (Figure 7, Item 1).
e. Wash screen (Figure 7, Item 5) in
nonflammable solvent and dry screen
f. Install washer and screen (Figure
7, Item 5) in torque converter housing
(Figure 7, Item 4).
g. Connect hose (Figure 7, Item 1),
two split clamps, four washers (Figure
7, Item 2), and bolts (Figure 7, Item 3)
to torque converter housing (Figure 7,
Item 4).
h. Install middle bottom guards, refer
to WP 0199.
0039-16