TM 5-2410-241-23-1
0039
Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued.
LOCATION
ITEM TO
CHECK/
ITEM
NOT FULLY MISSION
NO.
INTERVAL
PROCEDURE
CAPABLE IF:
SERVICE
a. Clean transmission magnetic
16
Every 1,000
Magnetic screen plugged.
Transmission
Service
screen when transmission oil is
Magnetic
Hours or six
changed.
Screen - Clean
months
b. Remove middle bottom guards,
(WP 0199).
c. Remove four nuts (Figure 8,
Item 1), cover (Figure 8, Item 2), O-
ring (Figure 8, Item 4) and spring
washer (Figure 8, Item 5) from housing
(Figure 8, Item 3).
d. Remove screen (Figure 8, Item 7)
and magnetic assembly (Figure 8,
Item 8) from housing (Figure 8,
Item 3).
e. Clean screen (Figure 8, Item 7) and
magnetic assembly (Figure 8, Item 8)
in nonflammable solvent.
f. Install new O-ring (Figure 8, Item 4)
on cover (Figure 8, Item 2).
g. Install screen (Figure 8, Item 7) and
magnetic assembly (Figure 8, Item 8)
in housing (Figure 8, Item 3).
h. Install spring washer (Figure 8,
Item 5), cover (Figure 8, Item 2), and
four nuts (Figure 8, Item 1) on housing
(Figure 8, Item 3).
i. Install middle bottom guards,
(WP 0199).
0039-18