Figure 9. Alternator Connection.
Figure 11. Torque Converter Connections.

Field Maintenance Manual 1 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1176    1177    1178    1179    1180  1181  1182    1183    1184    1185    1186  
img
.
TM 5-2410-241-23-1
0055
REMOVAL CONTINUED
N OT E
Note harness routing to aid installation.
Tag and mark all electrical connections to aid installation.
25. Disconnect engine main harness connector (Figure 10, Item 2) from transmission temperature sensor
connector (Figure 10, Item 1).
26. Remove tiedown straps (Figure 10, Item 3) from engine main harness (Figure 10, Item 4). Discard tiedown
straps.
Figure 10. Transmission Temperature Connections.
0055
0055-10