Figure 4. ECM Connections.
Figure 6. Platform Harness Connections.

Field Maintenance Manual 1 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1171    1172    1173    1174    1175  1176  1177    1178    1179    1180    1181  
img
.
TM 5-2410-241-23-1
0055
REMOVAL CONTINUED
N OT E
Note harness routing to aid installation.
Tag and mark all electrical connections to aid installation.
Note number and location of tiedown straps to aid installation.
7. Disconnect engine main harness connector (Figure 5, Item 3) from underhood work light switch connector
(Figure 5, Item 2).
8. Position connector (Figure 5, Item 1) aside.
9. Remove tiedown straps (Figure 5, Item 4) from engine main harness (Figure 5, Item 5). Discard tiedown
straps.
10. Disconnect engine main harness connector (Figure 5, Item 6) from light (Figure 5, Item 7).
11. Position engine main harness (Figure 5, Item 5) aside.
Figure 5. Underhood Work Light Connection.
0055
0055-5