TM 5-2410-241-23-1
0054
CLEANING AND INSPECTION
00054
Clean and inspect all parts IAW Mechanical General Maintenance Instructions (WP 0295).
END OF TASK
INSTALLATION
00054
N OT E
Install electrical connections and harness routing as noted during removal.
1. Install air inlet temperature sensor harness (Figure 2, Item 4) on machine.
2. Connect connector (Figure 2, Item 6) on connector (Figure 2, Item 5).
3. Install new tiedown strap (Figure 2, Item 1) on air inlet temperature sensor harness (Figure 2, Item 4).
4. Connect connector (Figure 2, Item 3) on air inlet temperature sensor (Figure 2, Item 2).
Figure 2. Fuel Temperature Sensor Harness.
0054
END OF TASK
FOLLOW-ON TASKS
00054
Verify correct operation of machine (TM 5-2410-241-10).
END OF TASK
END OF WORK PACKAGE