• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
CLEANING AND INSPECTION
Figure 2. Hub Upper Mount.

Field Maintenance Manual D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  356    357    358    359    360  361  362    363    364    365    366  
img
. . . .
14
TM 5-2410-241-23-2
0095
FIELD MAINTENANCE
-
FAN HUB PULLEY REPLACEMENT
009
5
Removal, Cleaning and Inspection, Installation
INITIAL SETUP
References
Tools and Special Tools
0
0
Tool Kit, General Mechanic's
WP 0295
0
(WP 0302, Item 65)
0
Equipment Condition
0
Lifting Device (500 lb capacity)
0
Machine parked (TM 5-2410-241-10)
Sling, Multiple Leg (WP 0302, Item 54)
0
0
Cooling fan removed (WP 0050)
0
Materials/Parts
V-belt set (Alternator) removed (WP 0098)
0
0
Rag, Wiping (WP 0303, Item 24)
V-belt (A/C compressor) removed (WP 0096)
0
0
Emery Cloth
Hood removed (WP 0200)
0
0
Locknut (2)
0
Drawing Required
0
Roll Pin
0
TM 5-2410-241-24P, Figure 6, 7
Seal
0
0
Estimated Time to Complete
Personnel Required
0
0
4.0 Hr
Two
0
0
REMOVAL
00095
1. Remove two locknuts (Figure 1, Item 1) and washers (Figure 1, Item 2) from plate (Figure 1, Item 3). Discard
locknuts.
Figure 1. Hub Lower Mount.
0095
0095-1