Figure 9. Pump O-rings.
Figure 12. Hoses.

Field Maintenance Manual D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  712    713    714    715    716  717  718    719    720    721    722  
img
.
TM 5-2410-241-23-2
0141
INSTALLATION CONTINUED
WARN I N G
Use extreme caution when handling heavy parts. Provide adequate support and use
assistance during procedure. Ensure lifting device used is in good condition and of
suitable load capacity. Keep clear of heavy parts supported only by lifting device. Failure
to follow this warning may cause injury or death to personnel.
N OT E
Gear pump weighs approximately 90 lb (41 kg).
2. Attach sling and chain hoist to pump (Figure 10, Item 1).
3. Using chain hoist, install pump (Figure 10, Item 1), two washers (Figure 10, Item 3), and bolts (Figure 10,
Item 2) on machine.
4. Install two washers (Figure 10, Item 5) and nuts (Figure 10, Item 4) on pump (Figure 10, Item 1).
5. Remove sling and chain hoist from pump (Figure 10, Item 1).
Figure 10. Pump.
0141
0141-9