TM 5-2410-241-23-2
0183
REMOVAL CONTINUED
2. Cut and discard tiedown strap (Figure 2, Item 3) from electrical connector (Figure 2, Item 2).
N OT E
Tag connector to aid installation.
3. Disconnect electrical connector (Figure 2, Item 2) from backup alarm (Figure 2, Item 5).
4. Remove two nuts (Figure 2, Item 7), washers (Figure 2, Item 8), bolts (Figure 2, Item 1), washers (Figure 2,
Item 6), bracket (Figure 2, Item 4), and backup alarm (Figure 2, Item 5) from machine.
Figure 2. Backup Alarm.
0183
END OF TASK
CLEANING AND INSPECTION
000183
Clean and inspect all parts IAW Mechanical General Maintenance Instructions (WP 0295).
END OF TASK
INSTALLATION
000183
1. Position backup alarm (Figure 2, Item 5) on machine and install bracket (Figure 2, Item 4), two washers
(Figure 2, Item 6), bolts (Figure 2, Item 1), washers (Figure 2, Item 8), and nuts (Figure 2, Item 7) on machine.
N OT E
Install connector as tagged during removal.
2. Connect electrical connector (Figure 2, Item 2) to backup alarm (Figure 2, Item 5).
3. Install new tiedown strap (Figure 2, Item 3) on electrical connector (Figure 2, Item 2).