Figure 6. Left Hand Door.
Figure 2. Backup Alarm.

Field Maintenance Manual D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1065    1066    1067    1068    1069  1070  1071    1072    1073    1074    1075  
img
. .
4
TM 5-2410-241-23-2
0183
FIELD MAINTENANCE INSTRUCTIONS
-
BACKUP ALARM REPLACEMENT
0
183
Removal, Cleaning and Inspection, Installation
INITIAL SETUP
References
Tools and Special Tools
0
0
Tool Kit, General Mechanic's
WP 0295
0
(WP 0302, Item 65)
0
Equipment Condition
0
Materials/Parts
Machine parked (TM 5-2410-241-10)
0
0
Rag, Wiping (WP 0303, Item 24)
0
Drawing Required
0
Tag, Marker (WP 0303, Item 34)
0
TM 5-2410-241-24P, Figure 96
Tiedown Strap (WP 0303, Item 36)
0
0
Estimated Time to Complete
0
0.5 Hr
0
REMOVAL
000183
1. Remove three bolts (Figure 1, Item 1), washers (Figure 1, Item 2), and cover (Figure 1, Item 3) from machine.