TM 5-2410-241-23-2
0190
INSTALLATION CONTINUED
N OT E
Install all hoses, tubes, and fittings as noted during removal.
6. Install two new O-rings (Figure 8, Items 6 and 7) on fitting (Figure 8, Item 2).
7. Install fitting (Figure 8, Item 2) on hydraulic tank (Figure 8, Item 3), and nut (Figure 8, Item 4) on fitting
(Figure 8, Item 2).
8. Install hose (Figure 8, Item 5) on fitting (Figure 8, Item 2).
9. Install hose (Figure 8, Item 1) on fitting (Figure 8, Item 2.
Figure 8. Lines.
0190