HYDRAULIC IMPLEMENT PUMP MAIN CONTROL VALVE HOSE REPLACEMENT
Figure 1. Implement Pump to Main Hydraulic Control Valve.

Field Maintenance Manual D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1165    1166    1167    1168    1169  1170  1171    1172    1173    1174    1175  
img
TM 5-2410-241-23-2
0193
REMOVAL
000193
WARN I N G
DO NOT disconnect or remove any hydraulic system hoses, tubes, or fittings unless
engine is shut down and hydraulic system pressure has been relieved. Tighten all
connections before applying pressure. Escaping hydraulic fluid under pressure can
penetrate skin.
At operating temperature, hydraulic oil is hot. Allow hydraulic oil to cool before removing
any hydraulic fitting.
To prevent injury to personnel, wear protective eye covering and gloves.
Failure to follow these warnings may result in injury or death to personnel.
C AU T I O N
Cap all hydraulic hose and tube ends along with component connections during removal
to protect against contamination. Failure to follow this caution may cause damage to
equipment.
N OT E
Tag hoses and fittings to aid installation.
Note routing of hose to aid installation.