Figure 3. Guard.
Figure 5. Disconnecting Lamp Connectors.

Field Maintenance Manual 3 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  200    201    202    203    204  205  206    207    208    209    210  
img
.
TM 5-2410-241-23-3
0210
DISASSEMBLY
000210
N OT E
Flood lamp can be disassembled without removing guard from machine.
1. Remove bolt (Figure 4, Item 1) and washer (Figure 4, Item 2). Open grille (Figure 4, Item 3).
2. Disengage and remove outer band clamp (Figure 4, Item 5) and pull lamp (Figure 4, Item 4) from grommet
(Figure 4, Item 6).
Figure 4. Flood Lamp Removal.
0210
0210-4