HEATER LINES REPLACEMENT
Figure 2. Right Side Connections.

Field Maintenance Manual 3 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  499    500    501    502    503  504  505    506    507    508    509  
img
.
TM 5-2410-241-23-3
0243
REMOVAL
000243
N OT E
Tag hoses to aid installation.
Cap and plug all hoses and lines to prevent contamination and leaks.
1. Close heater hose valve (Figure 1, Item 3).
2. Loosen clamp (Figure 1, Item 2) and remove hose (Figure 1, Item 1) from heater hose valve (Figure 1, Item 3).
3. Remove clamp (Figure 1, Item 2) from hose (Figure 1, Item 1).
4. Close heater hose valve (Figure 1, Item 6).
5. Loosen clamp (Figure 1, Item 5) and remove hose (Figure 1, Item 4) from heater hose valve (Figure 1, Item 6).
6. Remove clamp (Figure 1, Item 5) from hose (Figure 1, Item 4).
Figure 1. Heater Hose Shutoff Valves.
0243
0243-2