• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 12. Lock Tube Assembly.
Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued

Operator Manual D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  109    110    111    112    113  114  115    116    117    118    119  
img
TM 5-2410-240-10
0012
Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued
LOCATION
ITEM TO BE
CHECKED
OR
EQUIPMENT NOT
ITEM
MAN-
SERVICED
PROCEDURE
READY/AVAILABLE IF:
NO.
INTERVAL HOURS
19
Before
Radiator and
d. Check for damage or leaking
Damaged components, any
(Cont.)
Cooling Fan
components.
coolant leak, or Class III
hydraulic leaks are evident.
e. Check for and remove any
debris in cooling fan area and in
front of radiator.
f. Reposition and latch cooling fan
assembly.
g. Install lock tube assembly.
h. Close lower grill, then close
upper grill.
Figure 13.
Radiator and Cooling Fan.
0012
0012-16