Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued
LOCATION
ITEM TO BE
CHECKED
OR
EQUIPMENT NOT
ITEM
MAN-
SERVICED
PROCEDURE
READY/AVAILABLE IF:
NO.
INTERVAL HOURS
19
Before
Radiator and
d. Check for damage or leaking
Damaged components, any
(Cont.)
Cooling Fan
components.
coolant leak, or Class III
hydraulic leaks are evident.
e. Check for and remove any
debris in cooling fan area and in
front of radiator.
f. Reposition and latch cooling fan
assembly.
g. Install lock tube assembly.
h. Close lower grill, then close
upper grill.
Figure 13.
Radiator and Cooling Fan.
0012