TM 5-2410-240-10
0012
Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued
LOCATION
ITEM TO BE
CHECKED
OR
EQUIPMENT NOT
ITEM
MAN-
NO.
INTERVAL HOURS
SERVICED
PROCEDURE
READY/AVAILABLE IF:
Indicators and a. Turn the engine start switch to
23
Before
Monitor fails to enter
Gauges
ON position to initialize monitor
diagnostic test.
system automatic self-diagnostic
test.
b. Monitor the following:
1. All gauge pointers must
Any gauge does not move.
sweep left then right.
2. All alert indicators must
Any alert light does not
come on momentarily.
come on.
3. All segments in digital
Digital display panel
segment(s) inoperative.
display panel must come on
momentarily.
4. Action alarm must sound.
Action alarm does not
sound.
Figure 14.
Monitor System Display.
0012
24
Before
Dozer Blade
a. Start engine and run at low idle
b. Move the right joystick to most
Blade float indicator does
forward detent. Blade float
not come on.
indicator should be ON in
indicators and gauges display.