Table 2. Engine Troubleshooting with Codes - Continued.
Table 2. Engine Troubleshooting with Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  329    330    331    332    333  334  335    336    337    338    339  
img
. . . . . . . .
TM 5-2410-240-23-1
0019
Table 2. Engine Troubleshooting with Codes - Continued.
0019
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0001-06 Cylinder #1 Injector Current
8. Using digital multimeter
Continuity - Engine control wiring
Above Normal Continued
(WP 0283), test for continuity
harness is shorted. Replace
between engine ECM har-
engine control wiring harness
ness connector E-C1
(WP 0052). Verify proper operation
(WP 0018, Figure 102) termi-
of machine (TM 5-2410-240-10).
nal 57 and all other terminals
No Continuity - Proceed to step 9.
in engine ECM harness con-
nector E-C1 (WP 0018, F
igure 102). There should be
no continuity.
9. Using digital multimeter
Continuity - Engine control wiring
(WP 0283), test for continuity
harness is shorted. Replace
between engine ECM har-
engine control wiring harness
ness connector E-C1
(WP 0052). Verify proper operation
(WP 0018, Figure 102) termi-
of machine (TM 5-2410-240-10).
nal 57 and ground. There
No Continuity - ECM is faulty.
should be no continuity.
Replace engine ECM (WP 0049).
Connect E-C12 (WP 0018,
Figure 111) to H-C1 (WP 0018,
Figure 174) at valve cover base.
Verify proper operation of machine
(TM 5-2410-240-10).
Test Step 3: Test Forward Fuel
Injector Harness.
1. Turn ignition and battery dis-
connect switch to OFF posi-
tion (TM 5-2410-240-10).
2. Remove valve cover
(WP 0104).
3. Disconnect forward fuel injec-
tor harness terminal H-T3 and
terminal H-T4 (WP 0018,
Figure 269) from fuel injector
#1.
4. Using digital multimeter
Continuity - Forward fuel injector
(WP 0283), test for continuity
harness is shorted. Replace for-
between H-C1 (WP 0018,
ward fuel injector harness
Figure 174) harness connec-
(WP 0104). Verify proper operation
tor terminal 3 and all other ter-
of machine (TM 5-2410-240-10).
minals in H-C1 (WP 0018,
No Continuity - Proceed to step 5.
Figure 174) harness connec-
tor. There should be no conti-
nuity.
0019-15