TM 5-2410-240-23-1
0020
Table 2. Powertrain and Chassis Troubleshooting with Codes - Continued.
CID FMI CODE
Test or Inspection
Corrective Action
1703-03 Proportional Sole-
noid Valve (Forward Left
0283), test for continuity between
Drive Pump) Voltage Above
pin 48 on platform harness ECM
harness (WP 0150, WP 0155).
Normal - Continued
Ensure all harness connectors are
Figure 217) and all other pins on
reconnected. Verify proper operation
platform harness ECM J1 connec-
of machine (TM 5-2410-240-10).
No Continuity - Replace machine
0283), test for continuity between
ECM (WP 0147, WP 0149). Ensure all
pin 48 on platform harness ECM
harness connectors are reconnected.
Verify proper operation of machine
Figure 217) and all other pins on
(TM 5-2410-240-10).
platform harness ECM J2 connec-
harness (WP 0150, WP 0155).
Ensure all harness connectors are
reconnected. Verify proper operation
of machine (TM 5-2410-240-10).
N OT E
1703-05 Proportional Sole-
noid Valve (Forward Left
Always inspect harness connectors that are involved in circuit. Poor
Drive Pump) Current Below
connections can often be cause of an electrical circuit problem. Verify
Normal
that all connections in circuit are clean, secure and connections are in
good condition. If a problem with connection is found, correct problem
and verify diagnostic code is active before performing this procedure.
Tag wiring harnesses to aid installation.
1703-05 Code Active - Proceed to
machine control ECM and check
step 2.
No Codes Active - The problem does
not exist at this time. Resume normal
operation.
2. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
3. Disconnect pump harness LH for-
from LH forward pump solenoid.
4. Install a jumper wire between pins
1 and 2 on pump harness LH for-