CID FMI CODE
Test or Inspection
Corrective Action
1482-04 Sensor Power Sup-
32. Using digital multimeter (WP
No Continuity - Proceed to step 33.
ply (10 VDC) Voltage Below
0283), test for continuity between
Continuity - Replace cab harness
Normal - Continued
pin 45 on cab harness to platform
(WP 0233, WP 0234). Ensure all har-
harness connector C-C12 (WP
ness connectors are reconnected.
0018, Figure 22) and ground.
Verify proper operation of machine
(TM 5-2410-240-10).
33. Disconnect platform harness
ECM J1 connector PL-C4 (WP
0018, Figure 217) from machine
ECM (WP 0147, WP 0149).
34. Disconnect platform harness
ECM J2 connector PL-C5 (WP
0018, Figure 218) from machine
ECM (WP 0147, WP 0149).
35. Disconnect platform harness con-
nector PL-C2 (WP 0018, Figure
215) from machine ECM (WP
0149).
36. Using digital multimeter (WP
No Continuity - Proceed to step 37.
0283), test for continuity between
Continuity - Replace platform wiring
pin 69 on platform harness ECM
harness (WP 0150, WP 0155).
J1 connector PL-C4 (WP 0018,
Ensure all harness connectors are
Figure 217) and all other pins on
reconnected. Verify proper operation
platform harness ECM J1 connec-
of machine (TM 5-2410-240-10).
tor PL-C4 (WP 0018, Figure 217).
37. Using digital multimeter (WP
No Continuity - Proceed to step 38.
0283), test for continuity between
Continuity - Replace platform wiring
pin 69 on platform harness ECM
harness (WP 0150, WP 0155).
J1 connector PL-C4 (WP 0018,
Ensure all harness connectors are
Figure 217) and ground.
reconnected. Verify proper operation
of machine (TM 5-2410-240-10).
38. Using digital multimeter (WP
No Continuity - Proceed to step 39.
0283), test for continuity between
Continuity - Replace platform wiring
pin 69 on platform harness ECM
harness (WP 0150, WP 0155).
J1 connector PL-C4 (WP 0018,
Ensure all harness connectors are
Figure 217) and all pins on plat-
reconnected. Verify proper operation
form harness ECM J2 connector
of machine (TM 5-2410-240-10).
PL-C5 (WP 0018, Figure 218).