Table 1. Window Wiper and Washer Troubleshooting Procedures - Continued.
Table 1. Window Wiper and Washer Troubleshooting Procedures - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  949    950    951    952    953  954  955    956    957    958    959  
img
. . . . . . . .
TM 5-2410-240-23-1
0022
Table 1. Window Wiper and Washer Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4. Right Door Wiper Does
9. Using digital multimeter, test for
No Continuity - Proceed to step 10.
continuity (WP 0283) between
Not Operate Properly
Continuity - Replace right door wiper
right door wiper motor harness
Continued
motor jumper harness (WP 0209).
connector RW-C2 (WP 0018, Fig-
Ensure all harness connectors are
ure 241) terminal 2 and cab
reconnected. Install a new #11 15A
ground.
fuse (TM 5-2410-240-10). Verify
proper operation of machine (TM 5-
2410-240-10).
10. Using digital multimeter, test for
No Continuity - Proceed to step 11.
continuity (WP 0283) between
Continuity - Replace right door wiper
right door wiper motor harness
motor jumper harness (WP 0209).
connector RW-C2 (WP 0018, Fig-
Ensure all harness connectors are
ure 241) terminal 2 and all other
reconnected. Install a new #11 15A
terminals on conductor RW-C2.
fuse (TM 5-2410-240-10). Verify
proper operation of machine (TM 5-
2410-240-10).
11. Using digital multimeter, test for
No Continuity - Proceed to step 12.
continuity (WP 0283) between
Continuity - Replace right door wiper
right door wiper motor harness
motor jumper harness (WP 0209.
connector RW-C2 (WP 0018, Fig-
Ensure all harness connectors are
ure 241) terminal 3 and cab
reconnected. Install a new #11 15A
ground.
fuse (TM 5-2410-240-10). Verify
proper operation of machine (TM 5-
2410-240-10).
12. Using digital multimeter, test for
No Continuity - Proceed to step 13.
continuity (WP 0283) between
Continuity - Replace right door wiper
right door wiper motor harness
motor jumper harness (WP 0209).
connector RW-C2 (WP 0018, Fig-
Ensure all harness connectors are
ure 241) terminal 3 and all other
reconnected. Install a new #11 15A
terminals on conductor RW-C2.
fuse (TM 5-2410-240-10). Verify
proper operation of machine (TM 5-
2410-240-10).
13. Disconnect harness connector
PL-C1 (WP 0018, Figure 214)
from harness connector C-C12
(WP 0018, Figure 22).
14. Disconnect harness connector
PL-C3 (WP 0018, Figure 216)
from harness connector FP-C3
(WP 0018, Figure 168).
0022-44