TM 5-2410-240-23-1
0022
Table 1. Window Wiper and Washer Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4. Right Door Wiper Does
No Continuity - Proceed to step 16.
Not Operate Properly
Continuity - Replace platform har-
harness connector PL-C23 (WP
Continued
ness (WP 0150, WP 0155). Ensure all
0018, Figure 227) terminal 4 and
harness connectors are reconnected.
cab ground.
Install a new #11 15A fuse (TM 5-
2410-240-10). Verify proper operation
of machine (TM 5-2410-240-10).
No Continuity - Proceed to step 17.
Continuity - Replace platform har-
harness connector PL-C23 (WP
ness (WP 0150, WP 0155). Ensure all
0018, Figure 227) terminal 4 and
harness connectors are reconnected.
all other terminals on conductor
Install a new #11 15A fuse (TM 5-
PL-C23.
2410-240-10). Verify proper operation
of machine (TM 5-2410-240-10).
No Continuity - Proceed to step 18.
Continuity - Replace platform har-
harness connector PL-C23 (WP
ness (WP 0150, WP 0155). Ensure all
0018, Figure 227) terminal 2 and
harness connectors are reconnected.
cab ground.
Install a new #11 15A fuse (TM 5-
2410-240-10). Verify proper operation
of machine (TM 5-2410-240-10).
No Continuity - Proceed to step 19.
Continuity - Replace platform har-
harness connector PL-C23 (WP
ness (WP 0150, WP 0155). Ensure all
0018, Figure 227) terminal 2 and
harness connectors are reconnected.
all other terminals on conductor
Install a new #11 15A fuse (TM 5-
PL-C23.
2410-240-10). Verify proper operation
of machine (TM 5-2410-240-10).
No Continuity - Proceed to step 20.
Continuity - Replace platform har-
harness connector PL-C23 (WP
ness (WP 0150, WP 0155). Ensure all
0018, Figure 227) terminal 3 and
harness connectors are reconnected.
cab ground.
Install a new #11 15A fuse (TM 5-
2410-240-10). Verify proper operation
of machine (TM 5-2410-240-10).
No Continuity - Proceed to step 21.
Continuity - Replace platform har-
harness connector PL-C23 (WP
ness (WP 0150, WP 0155). Ensure all
0018, Figure 227) terminal 3 and
harness connectors are reconnected.
all other terminals on conductor
Install a new #11 15A fuse (TM 5-
PL-C23.
2410-240-10). Verify proper operation
of machine (TM 5-2410-240-10).
0022-45