Table 1. Window Wiper and Washer Troubleshooting Procedures - Continued.
Table 1. Window Wiper and Washer Troubleshooting Procedures - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  950    951    952    953    954  955  956    957    958    959    960  
img
. . . . . . . . . . . .
TM 5-2410-240-23-1
0022
Table 1. Window Wiper and Washer Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4. Right Door Wiper Does
15. Using digital multimeter, test for
No Continuity - Proceed to step 16.
continuity (WP 0283) between
Not Operate Properly
Continuity - Replace platform har-
harness connector PL-C23 (WP
Continued
ness (WP 0150, WP 0155). Ensure all
0018, Figure 227) terminal 4 and
harness connectors are reconnected.
cab ground.
Install a new #11 15A fuse (TM 5-
2410-240-10). Verify proper operation
of machine (TM 5-2410-240-10).
16. Using digital multimeter, test for
No Continuity - Proceed to step 17.
continuity (WP 0283) between
Continuity - Replace platform har-
harness connector PL-C23 (WP
ness (WP 0150, WP 0155). Ensure all
0018, Figure 227) terminal 4 and
harness connectors are reconnected.
all other terminals on conductor
Install a new #11 15A fuse (TM 5-
PL-C23.
2410-240-10). Verify proper operation
of machine (TM 5-2410-240-10).
17. Using digital multimeter, test for
No Continuity - Proceed to step 18.
continuity (WP 0283) between
Continuity - Replace platform har-
harness connector PL-C23 (WP
ness (WP 0150, WP 0155). Ensure all
0018, Figure 227) terminal 2 and
harness connectors are reconnected.
cab ground.
Install a new #11 15A fuse (TM 5-
2410-240-10). Verify proper operation
of machine (TM 5-2410-240-10).
18. Using digital multimeter, test for
No Continuity - Proceed to step 19.
continuity (WP 0283) between
Continuity - Replace platform har-
harness connector PL-C23 (WP
ness (WP 0150, WP 0155). Ensure all
0018, Figure 227) terminal 2 and
harness connectors are reconnected.
all other terminals on conductor
Install a new #11 15A fuse (TM 5-
PL-C23.
2410-240-10). Verify proper operation
of machine (TM 5-2410-240-10).
19. Using digital multimeter, test for
No Continuity - Proceed to step 20.
continuity (WP 0283) between
Continuity - Replace platform har-
harness connector PL-C23 (WP
ness (WP 0150, WP 0155). Ensure all
0018, Figure 227) terminal 3 and
harness connectors are reconnected.
cab ground.
Install a new #11 15A fuse (TM 5-
2410-240-10). Verify proper operation
of machine (TM 5-2410-240-10).
20. Using digital multimeter, test for
No Continuity - Proceed to step 21.
continuity (WP 0283) between
Continuity - Replace platform har-
harness connector PL-C23 (WP
ness (WP 0150, WP 0155). Ensure all
0018, Figure 227) terminal 3 and
harness connectors are reconnected.
all other terminals on conductor
Install a new #11 15A fuse (TM 5-
PL-C23.
2410-240-10). Verify proper operation
of machine (TM 5-2410-240-10).