Table 1. Window Wiper and Washer Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4. Right Door Wiper Does
5. Using digital multimeter, check for
No Continuity - Proceed to step 6.
Not Operate Properly
continuity (WP 0283) between
Continuity - Replace washer pump
Continued
right door washer pump harness
harness (WP 0153, WP 0154).
connector WP-C2 (WP 0018, Fig-
Ensure all harness connectors are
ure 223) terminal 1 and 2.
reconnected. Install a new #26 15A
fuse (TM 5-2410-240-10). Verify
proper operation of machine (TM 5-
2410-240-10).
6. Disconnect harness connector
CH-C1 (WP 0018, Figure 81) from
harness connector PL-C18 (WP
0018, Figure 226).
7. Using digital multimeter, test for
No Continuity - Proceed to step 8.
continuity (WP 0283) between
Continuity - Replace chassis harness
harness connector CH-C26 (WP
(WP 0153, WP 0154). Ensure all har-
0018, Figure 97) terminal 5 and
ness connectors are reconnected.
cab ground.
Install a new #26 15A fuse (TM 5-
2410-240-10). Verify proper operation
of machine (TM 5-2410-240-10).
8. Using digital multimeter, test for
No Continuity - Proceed to step 9.
continuity (WP 0283) between
Continuity - Replace chassis harness
harness connector CH-C26 (WP
(WP 0153, WP 0154). Ensure all har-
0018, Figure 97) terminal 5 and
ness connectors are reconnected.
all other terminals in connector
Install a new #26 15A fuse (TM 5-
CH-C26 (WP 0018, Figure 97).
2410-240-10). Verify proper operation
of machine (TM 5-2410-240-10).
9. Disconnect harness connector
PL-C1 (WP 0018, Figure 214)
from harness connector C-C12
(WP 0018, Figure 22).
10. Using digital multimeter, test for
No Continuity - Proceed to step 11.
continuity (WP 0283) between
Continuity - Replace platform har-
harness connector PL-C18 (WP
ness (WP 0150, WP 0155). Ensure all
0018, Figure 226) terminal 36 and
harness connectors are reconnected.
cab ground.
Install a new #26 15A fuse (TM 5-
2410-240-10). Verify proper operation
of machine (TM 5-2410-240-10).
11. Using digital multimeter, test for
No Continuity - Proceed to step 12.
continuity (WP 0283) between
Continuity - Replace platform har-
harness connector PL-C18 (WP
ness (WP 0150, WP 0155). Ensure all
0018, Figure 226) terminal 36 and
harness connectors are reconnected.
all other terminals in connector
Install a new #26 15A fuse (TM 5-
PL-C18 (WP 0018, Figure 226).
2410-240-10). Verify proper operation
of machine (TM 5-2410-240-10).