Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1061    1062    1063    1064    1065  1066  1067    1068    1069    1070    1071  
img
. . . . . . . .
TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
N OT E
1885-03 Winch Spool Out
Solenoid Voltage Above Nor-
Always inspect harness connectors thatare involved in the circuit. Poor
mal
connections can often be the cause of an electrical circuit problem. Ver-
ify that all connections in circuit are clean and secure, and connections
are in good condition. If a problem with connection is found, correct the
problem and verify diagnostic code is active before performing this pro-
cedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Tag wiring harnesses to aid installation.
Perform this test only if condition is active.
Test Step 1. Test for Shorted Pump
Wiring Harness.
1. Connect MSD (WP 0016). Select
machine control D6K ECM and
verify 1885-03 is active.
2. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
3. Remove right side debris guards
from machine (WP 0187).
4. Disconnect pump wiring harness
connector PH-C1 (WP 0018, Fig-
ure 205) from engine wiring har-
ness connector EN-C21 (WP
0018, Figure 137) (WP 0046).
5. Turn battery disconnect switch
and ignition switch to ON position
(TM 5-2410-240-10).
Code 1885-03 Remains Active - Pro-
6. Check for active code 1885-03 in
ceed to Test Step 2.
machine control D6K ECM (WP
0016).
Code 1885-03 Becomes Inactive -
Replace pump wiring harness (WP
0046).
Proceed to step 7.
7. Using MSD (WP 0016), select
Code 1885-03 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 1885-03 is not active.
Code 1885-03 Not Active - Trouble-
shooting complete.
0023-104