• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1060    1061    1062    1063    1064  1065  1066    1067    1068    1069    1070  
img
. . . . . . . . . . . . .
TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
1884-06 Winch Spool In
Continuity on Test Point - Replace
Solenoid Current Above
platform wiring harness (WP 0155).
Normal - Continued
Connect pump wiring harness con-
nector PH-C1 (WP 0018, Figure 205)
on engine wiring harness connector
EN-C21 (WP 0018, Figure 137) (WP
0046).
Connect pump wiring harness con-
nector PH-C8 on reel-in solenoid (WP
0018, Figure 212) (WP 0267).
Install right side debris guards (WP
0187).
Install front floor plate on machine
(WP 0205).
Proceed to step 9.
9. Using MSD (WP 0016), select
Code 1884-03 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 1884-03 is not active.
Code 1884-03 Not Active - Trouble-
shooting complete.
1884-13 Winch Spool In
Test Step 1. Check for Active Cali-
Solenoid Out of Calibration
bration Code.
1. Connect MSD (WP 0016). Select
machine control D6K ECM and
verify 1884-13 is active.
2. Perform calibration of winch
spool-in solenoid (WP 0033).
Code 1884-13 Remains Active - Pro-
3. Check for active code 1884-13 in
ceed to Test Step 2.
machine control D6K ECM (WP
0016).
Code 1884-13 Becomes Inactive -
Troubleshooting complete.
Test Step 2. Verify Equipment ECM
Is Programmed Correctly.
1. Verify equipment (Implement
Software Correct - Replace equip-
Control #2) ECM is flashed with
ment ECM (WP 0148).
correct software (WP 0017).
Proceed to step 2.
Software Incorrect - Flash equip-
ment (Implement Control #2) ECM
with correct software (WP 0017). Pro-
ceed to step 2.
2. Check for active code 1884-13 in
Code 1884-13 Active - Repeat trou-
machine control D6K ECM (WP
bleshooting code from the beginning.
0016).
Code 1884-13 Not Active - Trouble-
shooting complete.
0023-103


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.