Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
1884-05 Winch Spool In
Code 1884-05 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
mal - Continued
verify 1884-05 is not active.
Code 1884-05 Not Active - Trouble-
shooting complete.
N OT E
1884-06 Winch Spool In
Always inspect harness connectors thatare involved in the circuit. Poor
Normal
connections can often be the cause of an electrical circuit problem. Ver-
ify that all connections in circuit are clean and secure, and connections
are in good condition. If problem with connection is found, correct the
problem and verify diagnostic code is active before performing this pro-
cedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Tag wiring harnesses to aid installation.
Perform this test only if condition is active.
Test Step 1. Test for Shorted Reel-
In Solenoid.
machine control D6K ECM and
verify 1884-06 is active.
2. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
3. Remove front floor plate from
machine (WP 0205).
4. Disconnect pump wiring harness
connector PH-C8 from reel-in
(WP 0267).
5. Turn battery disconnect switch
and ignition switch to ON position
(TM 5-2410-240-10).
Code 1884-06 Remains Active - Pro-
6. Check for active code 1884-05 or
ceed to Test Step 2.
1884-06 in machine control D6K
Code 1884-06 Becomes Inactive
and 1884-05 Becomes Active -
Replace reel-in solenoid (WP 0132).
Proceed to step 7.
Code 1884-06 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 1884-06 is not active.
Code 1884-06 Not Active - Trouble-
shooting complete.