Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1052    1053    1054    1055    1056  1057  1058    1059    1060    1061    1062  
img
. . . . . . .
TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
1884-05 Winch Spool In
6. Check for active code 1884-05 or
Code 1884-05 Remains Active - Pro-
Solenoid Current Below Nor-
1884-06 in machine control D6K
ceed to Test Step 4.
mal - Continued
ECM (WP 0016).
Code 1884-05 Becomes Inactive
and 1884-06 Becomes Active - Turn
ignition switch and battery disconnect
switch to OFF position (TM 5-2410-
240-10).
Remove jumper wire from PL-C32 ter-
minal 2 and 3 (WP 0018, Figure 232).
Replace engine wiring harness (WP
0046).
Connect pump wiring harness con-
nector PH-C8 on reel-in solenoid (WP
0018, Figure 212) (WP 0267).
Install front floor plate on machine
(WP 0205).
Proceed to step 7.
7. Using MSD (WP 0016), select
Code 1884-05 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 1884-05 is not active.
Code 1884-05 Not Active - Trouble-
shooting complete.
Test Step 4. Test F869-PK Reel-In
Solenoid Supply Circuit for High
Resistance or Open in Platform
Wiring Harness.
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
2. Remove jumper wire from PL-C32
terminal 2 and 3 (WP 0018, Fig-
ure 232).
3. Disconnect platform wiring har-
ness connector PL-C2 (WP 0018,
Figure 215) from equipment ECM
(WP 0148).
0023-95