TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
1885-06 Winch Spool Out
4. Disconnect pump wiring harness
connector PH-C9 from reel-out
Normal - Continued
(WP 0267).
5. Turn battery disconnect switch
and ignition switch to ON position
(TM 5-2410-240-10).
6. Check for active code 1885-05 or
Code 1885-06 Remains Active - Pro-
1885-06 in machine control D6K
ceed to Test Step 2.
Code 1885-06 Becomes Inactive
and 1885-05 Becomes Active -
Proceed to step 7.
Code 1885-06 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 1885-06 is not active.
Code 1885-06 Not Active - Trouble-
shooting complete.
Test Step 2. Test for Shorted Pump
Wiring Harness.
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
2. Remove right side debris guards
from machine (WP 0187).
3. Disconnect pump wiring harness
ure 205) from engine wiring har-
ness connector EN-C21 (WP
0018, Figure 137) (WP 0046).
4. Turn battery disconnect switch
and ignition switch to ON position
(TM 5-2410-240-10).
5. Check for active code 1885-05 or
Code 1885-06 Remains Active - Pro-
1885-06 in machine control D6K
ceed to Test Step 3.
Code 1885-06 Becomes Inactive
and 1885-05 Becomes Active -
Replace pump wiring harness (WP
0046).
Proceed to step 6.
Code 1885-06 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 1885-06 is not active.
Code 1885-06 Not Active - Trouble-
shooting complete.
0023-123