Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1124    1125    1126    1127    1128  1129  1130    1131    1132    1133    1134  
img
. . . . . . . . .
TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
1934-13 Blade Angle Right
Test Step 1. Check for Active Cali-
Solenoid Out of Calibration
bration Code.
1. Connect MSD (WP 0016). Select
machine control D6K ECM and
verify 1934-13 is active.
2. Perform calibration of blade angle
right solenoid (WP 0033).
3. Check for active code 1934-13 in
Code 1934-13 Remains Active - Pro-
machine control D6K ECM (WP
ceed to Test Step 2.
0016).
Code 1934-13 Becomes Inactive -
Troubleshooting complete.
Test Step 2. Verify Equipment ECM
Is Programmed Correctly.
1. Verify equipment (Implement
Software Correct - Replace equip-
Control #2) ECM is flashed with
ment ECM (WP 0148).
correct software (WP 0017).
Proceed to step 2.
Software Incorrect - Flash equip-
ment (Implement Control #2) ECM
with correct software (WP 0017). Pro-
ceed to step 2.
2. Check for active code 1934-13 in
Code 1934-13 Active - Repeat trou-
machine control D6K ECM (WP
bleshooting code from the beginning.
0016).
Code 1934-13 Not Active - Trouble-
shooting complete.
N OT E
2211-03 Auxiliary Valve #1
Port B Solenoid Voltage
Always inspect harness connectors thatare involved in the circuit. Poor
Above Normal
connections can often be the cause of an electrical circuit problem. Ver-
ify that all connections in circuit are clean and secure, and connections
are in good condition. If problem with connection is found, correct the
problem and verify diagnostic code is active before performing this pro-
cedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Tag wiring harnesses to aid installation.
Perform this test only if condition is active.
Test Step 1. Test for Shorted Chas-
sis Wiring Harness.
1. Connect MSD (WP 0016). Select
machine control D6K ECM and
verify 2211-03 is active.
2. Turn ignition switch and battery
disconnect switch to the OFF
position (TM 5-2410-240-10).