TM 5-2410-240-23-1
0027
HYDRAULIC FAN SPEED CALIBRATION AND ADJUSTMENT CONTINUED
Fan Speed Calibration Procedure
00027
1. Perform Preparation of Machine for Fan Speed Calibration in this work package.
2. Select engine ECM (Figure 7, Item 5) from Available ECM(s) list (Figure 7, Item 1).
3. Select Service menu (Figure 7, Item 2), Calibrations (Figure 7, Item 3), and Engine Cooling Fan Calibration
option (Figure 7, Item 4) to begin calibration procedure.
Figure 7. Engine Cooling Fan Calibration Menu.
0027