• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 4. Engine Oil Cooler.
HYDRAULIC FAN SPEED CALIBRATION AND ADJUSTMENT

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1270    1271    1272    1273    1274  1275  1276    1277    1278    1279    1280  
img
.
TM 5-2410-240-23-1
0027
HYDRAULIC COOLING FAN OPERATION
00027
1. Park machine (TM 5-2410-240-10).
2. Install ET and verify 0110-03, 0110-04, 0295-05, and 0295-05 diagnostic codes are not active. Diagnose if
codes are active.
3. Check cooling fan for correct operation.
a. If cooling fan operates slowly, check the following:
(1) Oil supply line for kinks, restrictions, and blockage.
(2) Demand fan manifold (Figure 5, Item 2) for blockage.
(3) Stuck demand fan manifold solenoid (Figure 5, Item 1).
(4) Perform Hydraulic Cooling Fan Calibration in this work package.
b. If cooling fan operates fast, verify circuits to demand fan manifold are not shorted.
Perform Hydraulic Cooling Fan Calibration in this work package.
Figure 5. Demand Fan Manifold.
0027
END OF TASK
0027-7