TM 5-2410-240-23-1
0028
AIR INLET AND EXHAUST SYSTEM INSPECTION CONTINUED
Wastegate Solenoid Lines Inspection
00028
1. Inspect line (Figure 5, Item 1) from intake manifold to wastegate solenoid (Figure 5, Item 3) for restriction,
kinks, and damage. Replace line if kinked or damaged (WP 0080).
2. Inspect line (Figure 5, Item 2) from wastegate solenoid (Figure 5, Item 3) to wastegate actuator for restriction,
kinks, and damage. Replace line if kinked or damaged (WP 0080).
Figure 5. Wastegate Solenoid and Lines.
0028
END OF TASK
TURBOCHARGER INSPECTION
00028
WARN I N G
Hot engine components can cause injury from burns. Before performing maintenance on
engine, allow engine and components to cool. Failure to follow this warning may result in
severe burns to personnel.
C AU T I O N
Keep all parts clean from contaminants. Contaminants may cause rapid wear and shorten
component life.
N OT E
Care must be taken to ensure fluids are contained during performance of inspection,
maintenance, testing, adjusting, and repair of product. Be prepared to collect fluid with
suitable containers before opening any compartment or disassembling any component
containing fluids. Dispose of all fluids in accordance with local regulations and mandates.