FUEL INJECTION PUMP TUBE REMOVAL CONTINUED

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  227    228    229    230    231  232  233    234    235    236    237  
img
.
TM 5-2410-240-23-2
0060
FUEL INJECTION PUMP TUBE REMOVAL CONTINUED
6. Remove two bolts (Figure 3, Item 2) and bracket (Figure 3, Item 1) from oil filter housing (Figure 3, Item 10).
N OT E
Note position and routing of all tiedown straps and harnesses to aid installation.
7. Remove tiedown strap (Figure 3, Item 3) from harness (Figure 3, Item 4). Discard tiedown strap.
8. Remove three tiedown straps (Figure 3, Item 8) from harness (Figure 3, Item 9). Discard tiedown straps.
9. Remove tiedown straps (Figure 3, Items 6 and 7) from harness (Figure 3, Item 5). Discard tiedown straps.
10. Position harness (Figure 3, Items 4, 9, and 5) up and aside.