Figure 2. Prime Pump Temperature Sensor and Harness.
Figure 4. Prime Pump Temperature Sensor and Harness.

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  299    300    301    302    303  304  305    306    307    308    309  
img
.
TM 5-2410-240-23-2
0070
REMOVAL CONTINUED
3. Position drain pan under machine and remove sensor (Figure 3, Item 1) and O-ring (Figure 3, Item 2) from
adapter (Figure 3, Item 3). Discard O-ring.
4. Remove adapter (Figure 3, Item 3) and O-ring (Figure 3, Item 4) from base (Figure 3, Item 5). Discard O-ring.
Figure 3. Adapter.
0070
END OF TASK
CLEANING AND INSPECTION
00070
Clean and inspect all parts IAW Mechanical General Maintenance Instructions (WP 0282).
END OF TASK
0070-4