REMOVAL CONTINUED
3. Position drain pan under machine and remove sensor (Figure 3, Item 1) and O-ring (Figure 3, Item 2) from
adapter (Figure 3, Item 3). Discard O-ring.
4. Remove adapter (Figure 3, Item 3) and O-ring (Figure 3, Item 4) from base (Figure 3, Item 5). Discard O-ring.
Figure 3. Adapter.
0070
END OF TASK
CLEANING AND INSPECTION
00070
Clean and inspect all parts IAW Mechanical General Maintenance Instructions (WP 0282).
END OF TASK