Figure 4. Prime Pump Temperature Sensor and Harness.
PRIME PUMP TOGGLE SWITCH ASSEMBLY REPLACEMENT

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  301    302    303    304    305  306  307    308    309    310    311  
img
.
TM 5-2410-240-23-2
0070
INSTALLATION CONTINUED
4. Open fuel supply valve (Figure 5, Item 3), install panel (Figure 5, Item 2), and close left engine door (Figure 5,
Item 1).
Figure 5. Door, Panel, and Fuel Shutoff.
0070
END OF TASK
FOLLOW-ON TASKS
00070
Verify correct operation of machine (TM 5-2410-240-10).
END OF TASK
END OF WORK PACKAGE