TM 5-2410-240-23-2
0070
INSTALLATION
00070
1. Install new O-ring (Figure 3, Item 4) and adapter (Figure 3, Item 3) on base (Figure 3, Item 5).
2. Install new O-ring (Figure 3, Item 2) and sensor (Figure 3, Item 1) on adapter (Figure 3, Item 3).
N OT E
Install wires and wiring harnesses as noted during removal.
3. Connect wiring harness (Figure 4, Item 3) on sensor connector (Figure 4, Item 2) and install two new tiedown
straps (Figure 4, Item 1) on machine.
Figure 4. Prime Pump Temperature Sensor and Harness.
0070