Figure 4. Prime Pump Level Sensor Probe.
PRIME PUMP FUEL TOGGLE SWITCH ASSEMBLY REPLACEMENT

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  310    311    312    313    314  315  316    317    318    319    320  
img
.
TM 5-2410-240-23-2
0072
PRIME PUMP LEVEL SENSOR PROBE INSTALLATION CONTINUED
N OT E
Install wires and wiring harnesses as noted during removal.
5. Open fuel supply valve (Figure 5, Item 3), install panel (Figure 5, Item 2), and close left engine door (Figure 5,
Item 1).
Figure 5. Door, Panel, and Fuel Shutoff.
0072
END OF TASK
FOLLOW ON-TASKS
00072
Verify correct operation of machine (TM 5-2410-240-10).
END OF TASK
END OF WORK PACKAGE
0072-6