• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 1. Door, Panel, and Fuel Shutoff.
Figure 3. Prime Pump Level Sensor.

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  307    308    309    310    311  312  313    314    315    316    317  
img
.
TM 5-2410-240-23-2
0072
PRIME PUMP LEVEL SENSOR PROBE REMOVAL CONTINUED
N OT E
Tag wires and wiring harnesses to aid installation.
2. Disconnect wire (Figure 2, Item 5) from sensor (Figure 2, Item 3). Position wire aside.
3. Position drain pan under machine and open drain valve (Figure 2, Item 4) on water separator (Figure 2, Item 1)
until fuel is completely drained.
4. Remove sensor (Figure 2, Item 3) from water separator (Figure 2, Item 1).
5. Remove O-ring (Figure 2, Item 2) from sensor (Figure 2, Item 3). Discard O-ring.
Figure 2. Prime Pump Level Sensor Probe.
0072
END OF TASK
0072-3