Figure 1. Left Front Access Door and Fuel Shutoff Valve.
Figure 4. Prime Pump Fuel Switch and O-ring.

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  313    314    315    316    317  318  319    320    321    322    323  
img
.
TM 5-2410-240-23-2
0073
REMOVAL CONTINUED
3. Remove tiedown strap (Figure 2, Item 4) from harness (Figure 2, Item 3) and from prime pump fuel switch
(Figure 2, Item 2). Discard tiedown strap.
N OT E
Tag and mark electrical connectors to aid installation.
4. Disconnect harness (Figure 2, Item 3) from prime pump fuel switch (Figure 2, Item 2). Position harness aside.
5. Position drain pan underneath machine.
6. Remove prime pump fuel switch (Figure 2, Item 2) from elbow (Figure 2, Item 1).
Figure 2. Prime Pump Fuel Switch Assembly.
0073
7. Remove O-ring (Figure 3, Item 1) from prime pump fuel switch (Figure 3, Item 2). Discard O-ring.
Figure 3. Prime Pump Fuel Switch and O-ring.
0073
END OF TASK