TM 5-2410-240-23-2
0092
INSTALLATION CONTINUED
N OT E
Install lower A/C line as noted during removal.
12. Connect A/C line (Figure 6, Item 6) on A/C compressor (Figure 6, Item 5).
N OT E
Install A/C line as noted during removal.
13. Install A/C line (Figure 6, Item 1) on A/C compressor (Figure 6, Item 5).
N OT E
Ensure A/C lines are properly seated before installing plate and bolt.
14. Install plate (Figure 6, Item 2) and bolt (Figure 6, Item 4) on A/C compressor (Figure 6, Item 5). Torque bolt to
18 5 lb-ft (25 7 Nm).
15. Install cap (Figure 6, Item 3) on A/C compressor (Figure 6 Item 5).
16. Install sensor (Figure 6, Item 8) on A/C compressor (Figure 6 Item 5).
17. Connect electrical connector (Figure 6, Item 7) on sensor (Figure 6, Item 8).
Figure 6. A/C Compressor.
0092
END OF TASK