TM 5-2410-240-23-2
0110
CLEANING AND INSPECTION
000110
Clean and inspect all components IAW Mechanical General Maintenance Instructions (WP 0282).
END OF TASK
INSTALLATION
000110
N OT E
The following procedure is for one hydrostatic hose. Use the same procedure for each
additional hydrostatic hose.
Install hoses as noted during removal.
1. Install two new O-rings on each fitting (Figure 1, Item 8).
2. Install two fittings (Figure 1, Item 8), cross over hose (Figure 1, Item 9) and two tube nuts (Figure 1, Item 7) on
motor (Figure 1, Item 6) and motor (Figure 1, Item 2).
3. Install two new O-rings (Figure 1, Item 4) on hydrostatic hose (Figure 1, Item 3).
4. Install two flanges (Figure 1, Item 10), hydrostatic hose (Figure 1, Item 3), eight washers (Figure 1, Item 11)
and bolts (Figure 1, Item 1) on pump (Figure 1, Item 4) and motor (Figure 1, Item 2).
END OF TASK
FOLLOW-ON TASKS
000110
1. Fill hydraulic fluid (WP 0160).
3. Verify correct operation of machine (TM 5-2410-240-10).
END OF TASK
END OF WORK PACKAGE
0110-3/(4 blank)