• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 1. Hydrostatic Drive Motor Speed Sensor.
HYDROSTATIC DRIVE MOTOR SOLENOID REPLACEMENT

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  731    732    733    734    735  736  737    738    739    740    741  
img
. .
TM 5-2410-240-23-2
0127
CLEANING AND INSPECTION
000127
Clean and inspect all components IAW Mechanical General Maintenance Instructions (WP 0282).
END OF TASK
INSTALLATION
000127
N OT E
The following procedure will install the left hydraulic drive motor speed sensor. Follow the
same procedure for the right hydraulic drive motor speed sensor.
Install connectors as noted during removal.
1. Install new O-ring (Figure 1, Item 6) on hydraulic filter bypass switch (Figure 1, Item 1).
2. Install hydraulic drive motor speed sensor (Figure 1, Item 1) and two bolts (Figure 1, Item 5) on drive motor
(Figure 1, Item 7).
3. Position harness (Figure 1, Item 3) on drive motor (Figure 1, Item 7).
4. Connect harness connector (Figure 1, Item 2) on hydraulic drive motor speed sensor (Figure 1, Item 1).
5. Install new tiedown strap (Figure 1, Item 4) on hydraulic drive motor speed sensor (Figure 1, Item 1).
END OF TASK
FOLLOW-ON TASKS
000127
1. Fill hydraulic oil (WP 0160).
2. Install rear bottom guards (WP 0156).
3. Verify correct operation of machine (TM 5-2410-240-10).
END OF TASK
END OF WORK PACKAGE
0127-3/(4 blank)