• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 5. Sensor and Solenoid on Drive Motor.
HYDROSTATIC DRIVE MOTOR SPEED SENSOR REPLACEMENT

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  728    729    730    731    732  733  734    735    736    737    738  
img
. . . . .
TM 5-2410-240-23-2
0126
INSTALLATION CONTINUED
N OT E
Steps 18 through 24 apply to left drive motor only.
Remove all caps or plugs from hydraulic hoses and fittings and install hoses as noted
during removal.
18. Install two new O-rings (Figure 6, Item 3) on fitting (Figure 6, Item 4).
19. Install fitting (Figure 6, Item 4) on drive motor (Figure 6, Item 8).
20. Connect hose (Figure 6, Item 7) to fitting (Figure 6, Item 4) and tighten nut (Figure 6, Item 9).
21. Install new O-ring (Figure 6, Item 2) on sensor (Figure 6, Item 1).
22. Install sensor (Figure 6, Item 1) on fitting (Figure 6, Item 4).
N OT E
Install electrical connectors and tiedown straps as noted during removal.
23. Connect harness (Figure 6, Item 6) on sensor (Figure 6, Item 1).
24. Install new tiedown strap (Figure 6, Item 5) on harness (Figure 6, Item 6) and sensor (Figure 6, Item 1).
Figure 6. Sensor and Solenoid on Drive Motor.
0126
FOLLOW-ON TASKS
000126
1. Install hydraulic fan gear pump (WP 0122).
2. Install winch implement pump (WP 0124).
3. Fill hydraulic fluid (WP 0160).
4. Install rear and middle bottom guards (WP 0156).
5. Verify correct operation of machine (TM 5-2410-240-10).
END OF TASK
END OF WORK PACKAGE
0126-8


Privacy Statement
Press Release
Contact