HYDROSTATIC DRIVE MOTOR SOLENOID REPLACEMENT
HYDROSTATIC DRIVE MOTOR SOLENOID REPLACEMENT - Continued

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  733    734    735    736    737  738  739    740    741    742    743  
img
.
TM 5-2410-240-23-2
0128
REMOVAL
000128
N OT E
The following procedure will remove the left hydraulic drive motor solenoid. Follow the
same procedure for the right hydraulic drive motor solenoid.
Tag and mark connectors to aid installation.
1. Remove tiedown strap (Figure 1, Item 4) from hydraulic drive motor solenoid (Figure 1, Item 5). Discard
tiedown strap.
2. Disconnect harness connector (Figure 1, Item 1) from hydraulic drive motor solenoid (Figure 1, Item 5).
3. Position harness (Figure 1, Item 6) aside.
4. Remove cap (Figure 1, Item 2), O-ring (Figure 1, Item 3) and hydraulic drive motor solenoid (Figure 1, Item 5)
from drive motor (Figure 1, Item 7). Discard O-ring.
Figure 1. Hydrostatic Drive Motor Solenoid.
0128
END OF TASK
CLEANING AND INSPECTION
000128
Clean and inspect all components IAW Mechanical General Maintenance Instructions (WP 0282).
END OF TASK