TM 5-2410-240-23-2
0133
REMOVAL
000133
N OT E
Tag and mark all electrical connections to aid installation.
1. Remove tiedown straps (Figure 1, Item 3) from cover (Figure 1, Item 4). Position cover aside.
2. Remove nut (Figure 1, Item 1) and two cables (Figure 1, Item 2) from starter (Figure 1, Item 5).
3. Remove bolt (Figure 1, Item 11), washer (Figure 1, Item 10), and clamp (Figure 1, Item 9) from frame (Figure 1,
Item 12) and cable (Figure 1, Item 8).
4. Remove bolt (Figure 1, Item 7), washer (Figure 1, Item 6), and cable (Figure 1, Item 8) from frame (Figure 1,
Item 12).
Figure 1. Starter Cables.