Figure 1. Hydrostatic Pump Solenoid Valve.
Figure 3. Hydrostatic Pump Solenoid Valve.

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  759    760    761    762    763  764  765    766    767    768    769  
img
.
TM 5-2410-240-23-2
0132
DISASSEMBLY
000132
1. Remove O-ring (Figure 2, Item 3) from cap (Figure 2, Item 4). Discard O-ring.
2. Remove O-ring (Figure 2, Item 1) from valve (Figure 2, Item 2). Discard O-ring.
Figure 2. Solenoid Valve.
0132
END OF TASK
CLEANING AND INSPECTION
000132
Clean and inspect all components IAW Mechanical General Maintenance Instructions (WP 0282).
END OF TASK
ASSEMBLY
000132
1. Install new O-ring (Figure 2, Item 1) on valve (Figure 2, Item 2).
2. Install new O-ring (Figure 2, Item 3) on cap (Figure 2, Item 4).
END OF TASK
0132-3