TM 5-2410-240-23-2
0134
INSTALLATION CONTINUED
WARN I N G
Use extreme caution when handling heavy parts. Provide adequate support and use
assistance during procedure. Ensure lifting device used is in good condition and of
suitable load capacity. Keep clear of heavy parts supported only by lifting device. Failure
to follow this warning may cause injury or death to personnel.
N OT E
Right hydrostatic drive piston pump weighs approximately 158 lb (72 kg).
7. Attach lifting device on right hydrostatic drive piston pump (Figure 17, Item 1).
8. Using lifting device and with assistance, install right hydrostatic drive piston pump (Figure 17, Item 1), four
washers (Figure 17, Item 3), and bolts (Figure 17, Item 2) on left hydrostatic drive piston pump (Figure 17, Item
4).
9. Remove lifting device from right hydrostatic drive piston pump (Figure 17, Item 1).
Figure 17. Right Hydraulic Piston Pump and Retaining Hardware.
0134