Figure 1. Winch Oil Pressure Sensor, Sensor Harness, Solenoid Harness, and Retaining Hardware.
Figure 3. Winch Oil Pressure Sensor and O-ring.

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  835    836    837    838    839  840  841    842    843    844    845  
img
.
TM 5-2410-240-23-2
0136
REMOVAL CONTINUED
C AU T I O N
Cap or plug hydraulic fitting during removal to protect against contamination. Failure to
follow this caution may result in damage to equipment.
N OT E
Use a container to catch any fluid that may drain from fitting. Dispose of fluid IAW local
policy and ordinances. Ensure all spills are cleaned up.
4. Remove winch oil pressure sensor (Figure 2, Item 1) and O-ring (Figure 2, Item 2) from fitting (Figure 2,
Item 3). Discard O-ring.
Figure 2. Winch Oil Pressure Sensor and O-ring.
0136
END OF TASK
0136-3